Product Description
SR1914 Ultrasonic Thickness Gauge
Main functions of SR1914
1. The only product using clear bright color OLED in the same product class.
2. Faster measurement update rate
3. The innovative A scanning snapshot function Marks the economical thickness gauge into digital age.
4. Industry's first economical digital thickness gauge
The zero measurement technology, high resolution, A scanning snapshot function is based on full digital technology.
The only real 0.01 mm resolution of ultrasonicthickness meter in the same product class.
5. Adopted the zero measurement technology
6. More practical function
Alarm, DIFF/RR%, Min/max Capture
Features:
Color 320*240 Pixels Display
A-Scan Snapshot
Echo-Echo Mode(Thru Paint&Coatings)
Stores 100000 Readings
Gain: Low, Medium or High for varying test conditions
SR1914D Ultrasonic Thickness Gauge
Main functions of SR1914D
1. The only product using clear bright color OLED in the same product class.
2. Faster measurement update rate
3. The innovative A scanning snapshot function Marks the economical thickness gauge into digital age.
4. Industry's first economical digital thickness gauge
The zero measurement technology, high resolution, A scanning snapshot function is based on ful digital technology.
The SR1914D now offers Through-Coating Thickness Measuring Capability
5. The only real 0.01 mm resolution of ultrasonicthickness meter in the same product class.
6. Adopted the zero measurement technology
7. More practical function
Alarm, DIFF/RR%, Min/max Capture
Features:
Color 320*240 Pixels Display
A-Scan Snapshot
Echo-Echo Mode(Thru Paint&Coatings)
Stores 100000 Readings
Gain: Low, Medium or High for varying test conditions
SR1914DL Ultrasonic Thickness Gauge
Main functions of SR1914DL
1. The only product using clear bright color OLED in the same product class.
2. Faster measurement update rate
3. The innovative A scanning snapshot function Marks the economical thickness gauge into digital age.
4. Industry's first economical digital thickness gauge
The zero measurement technology, high resolution, A scanning snapshot function is based on full digital technology.
The SR1914DL now offers Through-Coating Thickness Measuring Capability.
5. More memory, more convenient storage capability.
6. The only real 0.01 mm resolution of ultrasonicthickness meter in the same product class.
7. Adopted the zero measurement technology
8. More practical function
Alarm, DIFF/RR%, Min/max Capture
Features:
Color 320*240 Pixels Display
A-Scan Snapshot
Echo-Echo Mode(Thru Paint&Coatings)
Stores 100000 Readings
Gain: Low, Medium or High for varying test conditions
SR1914 Series Technical Specifications
Instrument Specifications |
Display Type |
2.4" color OLED, 320 * 240 pixels, contrast 10,000:1 |
Operating Principle |
Pulse echo with dual element transducers |
Measuring Range |
0.60mm to 508mm(0.025" to 20.00"), depending on material, probe and surface condition |
Measuring Resolution |
Selectable 0.01mm, 0.1mm (selectable 0.001", 0.01") |
Units |
Inch or Millimeter |
Gain |
Low, Medium or High for varying test conditions |
Display Mode |
Normal, Minimum / Maximum capture, DIFF/RR% |
V-Path Correction |
Automatic |
Update Rate |
Selectable 4Hz, 8Hz, 16Hz |
Material Velocity Range |
500 to 9999m/s (0.0197 to 0.3937in/us) |
Languages |
Selectable Chinese, English, Japanese |
Alarm Settings |
Minimum and Maximum alarms. Range of 0.25 mm to 508 mm (0.010" to 20.00").Dynamic waveform color change on alarm |
Power Requirements |
2 AA size batteries |
Operating Time |
Approximately 40 hours |
Instrument Shut-off |
Selectable ALWAYS ON or AUTO OFF after 5, 10, 20 minutes of inactivity |
Operating Temperature |
-10°C to +50°C (+10°F to +120°F) |
Size |
153mm * 76mm * 37mm(H * W * D) |
Weight |
280g including batteries |
|
SR1914 Standard Configuration
SR1914 thickness gauge |
1 |
Standard Probe |
1 |
Carrying Case |
1 |
Couplant |
1 |
Operating Mannual |
1 |
1.5AA Alkaline batteries |
2 |
|
SR1914 Series Probe/Transducer Specifications |
Model |
PT08 |
TC510 |
PT12 |
ZT12 |
PT06 |
PT04 |
GT12 |
Type |
SR1914 Standard |
SR1914D/SR1914DL Standard |
Standard |
Cast iron |
Small tube |
Fingertip |
High-Temperature |
Frequency |
5MHz |
5MHz |
5MHz |
2MHz |
7.5MHz |
10MHz |
5MHz |
Contact Diameter |
11mm |
13.5mm |
13.5mm |
17mm |
8mm |
6mm |
15mm |
Measurement Range |
0.8 to
100.0mm |
1.2 to
200.0mm |
1.0 to 200.0mm |
4.0 to
508.0mm |
0.8 to
30.0mm |
0.7 to 12.0mm |
4.0 to
80.0mm |
Temperature Range |
-10 to 70°C |
-10 to
70°C |
-10 to 70°C |
-10 to 70°C |
-10 to
70°C |
-10 to 70°C |
-20 to 300°C |
|
SR1914D Standard Configuration
SR1914D thickness gauge unit |
1 |
Standard Probe |
1 |
Carrying Case |
1 |
Couplant |
1 |
Operating Mannual |
1 |
1.5V AA Alkaline batteries |
2 |
|
SR1914DL Data Logger Option Features |
Capacity |
400 files, 100,000 readings |
File Structure |
Grid file |
Rows * Columns |
21 * 12 |
Communication Port |
USB 2.0 (Full Speed ) port |
Software |
DataView PC software |
|
SR1914DLStandard Configuration
SR1914DL thickness gauge unit |
1 |
Stand Probe |
1 |
Carrying Case |
1 |
Couplant |
1 |
Operating Mannual |
1 |
1.5AA Alkaline Batteries |
2 |
|