Portable: | Portable |
---|---|
Appliance: | Food Analysis, Medical Research, Biochemistry |
Certification: | ISO9001, CE |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
PH Combined Electrode with Glass Body | |||||||||||||||||||||||||
Note: Difference between the two models is the reference cell electrolyte. 65-IP is with solution form and can be refilled. 65-IIP is in gel form which last life time, not need to refill. |
|||||||||||||||||||||||||
|
type | measure range | applicable temperature | application (it can be add temperature compensation element according to client's need.) |
E-201 BNC + 1m cable |
0~14pH | 0~60°C | The crust of PC be able to endure hit, gelatin KC1 electrolytic liquid dispense with complementarity ,in order laboratory and locale general use. *(For PH-8414/ORP-8414, PH-2601, 2602, 2603) |
E-201C/E-210C BNC + 1m cable |
0~14pH | 0~60°C | The crust of PC be able to endure hit, it can supplement electrolytic liquid, in order laboratory and locale general use, superior testing accuracy. |
E201W PH | 0~14pH | 0~60°C | *(For PH-016, 016A,PHS-3C) |
E201W ORP | 0~±1999mv | 0~60°C | |
Temperature electrode (for PH meters) | |||
E-0101 (for PH-0101) | |||
type | specification | applicable temperature | application |
E201WM PH Dia.14×length 85mm BNC |
MeasuringRange: 0.00~14.00PH Resolution:0.01PH OperatingTemperature: 0°C~50°C AutomaticTemperature Compensation (ATC): 0°C~50°C Connection: BNC socket |
0~50°C | *(For PHT-026, 027, 028, PH-025, PH-02636, PH-02736, PH-0253, PH-025M, PH-025N) |
E201WM ORP Dia.14×length 85mm BNC |
Measuring Range: 0 ~ ±1999mV Resolution: 1mV Accuracy: ±0.1% F·S±1 digit Connection: 300cm cable with BNC socket Operating Temperature: 0°C~50°C ATC Weight: 41g |
0~50°C | *(For PHT-027, 028) |
E201WM Conductivity Dia.14×length 85mm BNC |
Measuring Range: 0~19.99ms/cm, 0~1999us/cm Resolution: 1us, 0.1mS Accuracy: ±1.5%+2 digits Connection: with BNC socket Operating Temperature: 0°C~50°C ATC K=1 Weight: 41g |
0~50°C | *(For PHT-026, 027, 028, PH-02636, PH-02736) |
type | specification | applicable temperature | application |
201DH PH 165mm×26mm×26mm |
MeasuringRange: 0.00~14.00PH Resolution:0.01PH OperatingTemperature: 0°C~50°C AutomaticTemperature Compensation (ATC): 0°C~50°C Connection: BNC socket |
0~50°C | *(For Online controller) Note: Waterproof, Suitable for Aquarium. |
201DH ORP 165mm×26mm×26mm BNC |
Measuring Range: 0 ~ ±1999mV Resolution: 1mV Accuracy: ±0.1% F·S±1 digit Connection: 300cm cable with BNC socket Operating Temperature: 0°C~50°C ATC Weight: 41g |
0~50°C | *(For Online controller) Note: Waterproof, Suitable for Aquarium. |
type | specification | applicable temperature | application |
208DH Conductivity electrode 165mm×26mm×26mm BNC (or cut-off ends) |
Measuring Range: 0~1999us/cm, 0~199.9mS Resolution: 1us, 0.1mS Accuracy: ±1.5%+2 digits Connection: with BNC socket Operating Temperature: 0°C~50°C ATC K=1 Weight: 41g |
0~50°C | *(For CD-208, CD-308) Note: Waterproof, Suitable for Aquar |
model | PH range | Resolution | °C | MPa | connect | MΩ (25°C) |
Zero electricity (PH) |
Theory slope % | Use range |
CT-1001 sewage |
0~14 | ±0.01PH | 0~50 | 0.6 | cable | ≤250 | 7±0.5 | >95 | Environment -protection sewage online check |
CT-1001 water |
0~14 | ±0.01PH | 0~50 | 0.6 | cable | ≤80 | 7±0.5 | >95 | High purify water |
Model
|
CT-1001
|
Temperature (º C)
|
0~50°C
|
Connection form
|
Cable (shielded cable)
|
Zero potentiometer (PH)
|
7±0.5
|
PH range
|
0 ~ 14
|
Withstanding pressure (MPa)
|
0.6
|
Internal resistanceMΩ(25ºC)
|
250
|
Theoretical percentageslope%
|
>95
|
Terminal Blocks
|
BNC head, Pin-type inserts, Y-piece inserts
|
Overall connection
|
3/4 inch outer thread
|
Size
|
188*31mm
|
Model
|
CT-1001C
|
Temperature (º C)
|
0~50°C
|
Temperature compensation | Yes |
Connection form
|
Cable (shielded cable)
|
Zero potentiometer (PH)
|
7±0.5
|
PH range
|
0 ~ 14
|
Resolution | ±0.01PH |
Withstanding pressure (MPa)
|
0.6
|
Internal resistanceMΩ(25ºC)
|
250
|
Theoretical percentageslope%
|
>95
|
Terminal Blocks
|
BNC head, Y-piece inserts
|
Overall connection
|
3/4 inch outer thread
|
Size
|
188*31mm
|
model | PH range |
Resolution | °C | MPa | connect | MΩ (25°C) |
Zero electricity (PH) | Theory slope % | Use range |
CT-1002 sewage |
0~14 | ±0.01PH | 0~90 | 0.4 | cable | ≤250 | 7±0.5 | >95 | Environment -protection sewage online check |
CT-1002 water |
0~14 | ±0.01PH | 0~90 | 0.4 | cable | ≤80 | 7±0.5 | >95 | High purify water |