outdoor shielded Cat 6 cable, FTP cat6 cable
, cat6 cable, network cable
SFTP CAT6
1. 0.575mm BC or CCA, Al foiled, solid or stranded BC. 2.Standard: UL444, TIA/EIA568B, YD/T1002
SFTP CAT6
sftp cat6 cable
1.Application:
Voice, T1, ISDN
10BASE-T, 100BASE-T Fast Ethernet (IEEE 802.3),
100 VG - anyLAN(IEEE802.12), 155/622 Mbps ATM
550 MHz Broadband Vedio
1000BASE-T Gigabit Ethernet
2.STANDARD COMPLIANCES:
All Proposed Category 6 requirements as per ANSI/TIA/EIA, ISO/IEC, and CENELEC EN Standards, ANSI/TIA/EIA 568-B.2-1 CAT.6
ISO/IEC 11801 CLASS E, 2nd Edition
IEC 61156-6
CENELEC EN 50173-1
CENELEC EN 50288-5-1,CENELEC EN 50288-5-2
Flame Retardancy is verified according to IEC 60332-1-2.
3. Electrical Performance
1. Spark Test 1050 V (AC)
2. Dielectric Strength 2500 V dc / 3 seconds
3. Insulation Resistance Test Min. 150 MO/Km
4. Conductor Resistance Max. 6.8 O/100m at 20
5. Resistance Unbalance Max. 2%
6. Capacitance Unbalance Max. 330 pF/100m
7. Mutual Capacitance Max. 5600 pF/100m
8. Impedance
64kHz 125O ± 20% 1~250MHz 100O ± 15%
Conductor |
Material |
Bare Copper |
Size |
23 AWG |
Construction |
1/0.560 ± 0.02 mm |
Insulation |
Material |
Foam-Skin PE |
Thickness |
Average: 0.414 mm Min. at any point: 0.364mm |
Material |
1.387 ± 0.05 mm |
Colors |
Blue/White-Blue , Orange/White-Orange |
Green/White-Green , Brown/White-Brown |
Elongation |
Min. 150 % |
Tensile strength |
Min. 0.51 Kg/mm² |
Shield |
Al-Mylar Type |
Aluminum foil on outside |
Mylar Type |
Braid |
Material |
Tinned Copper |
Coverage |
Min. 40% (Nom. 48 %) |
Sheath |
Material |
PVC |
LSZH |
Thickness |
Average: 0.54 mm |
Average: 0.54 mm |
Min. at any point: 0.40 mm |
Min. at any point: 0.40 mm |
Diameter |
7.2 ± 0.3 mm |
7.2 ± 0.3 mm |
Color |
Assorted upon request |
Assorted upon request |
Elongation |
Min. 100% |
Min. 125% |
Tensile strength |
Min. 1.407 Kg/mm² |
Min. 0.917 Kg/mm² |
168100Aging at 100 for 168Hrs |
:50%
Min.elongation retention:50%
:75%
Min.tensile strength retention:75% |
Min.elongation
retention:75%
Min.tensile
strength retention:70% |
Frequency
MHz |
Attenuation
(dB/100 meters at 20),Max. |
Next
(dB),Min. |
Power sum
(dB),Min. |
0.772 |
|
67* |
64* |
1.0 |
|
65* |
62* |
4.0 |
6.4* |
56* |
53* |
8.0 |
8.9* |
51* |
48* |
10.0 |
9.9* |
50* |
47* |
16.0 |
12.3* |
47* |
44* |
20.0 |
13.8* |
45* |
42* |
25.0 |
16.0* |
44* |
41* |
31.25 |
17.1* |
42* |
39* |
62.5 |
25.6* |
38* |
35* |
100.0 |
100MHz |
33.0* |
32* |
125.0 |
37.4* |
34* |
31*
|