pH | Range | (-2.00 ~ 19.99)pH |
Resolution | 0.01/0.1 pH | |
Accuracy | ±0.01 pH ±1digit | |
Input current | ≤1×10-12 A | |
Input impedence | ≥1×1012 Ω | |
Stability | ±0.01 pH/3h ±1 digit | |
Temperature compensation | (0 ~ 100)°C (manual or automatic) | |
mV | Range | -1,999mV ~ 0 ~ 1,999mV |
Resolution | - 200 mV ~ 0 ~ 200 mV: 0.1 mV;others:1mV | |
Accuracy | ±0.1% FS ±1digit | |
Temperature | Range | 0~100°C |
Resolution | 0.1°C | |
Accuracy | ±0.5°C±1digit | |
Other Technical Parameters | Data storage | 500 groups |
Storage content | Serial number, date, time, measuring value, measuring unit and temperature value | |
Power | AAA batteries × 3 (1.5V× 3) / DC5V adaptor ( USB port) | |
Dimension & Weight | Meter: (88×170×33 )mm / 313g;Portable case: (360×270×76)mm/1.6kg | |
IP rating | IP57 dustproof and waterproof |
Conductivity | Range | Cond: 0~200mS/cm divided into five ranges: (0.00~19.99)μS/cm (20.0~199.9)μS/cm (200~1999)μS/cm (2.00~19.99)mS/cm (20.0~199.9)mS/cm TDS:(0 ~ 100)g/L Salinity: (0 ~ 100)ppt Resistivity: (0 ~ 100)MΩ·cm |
Resolution | 0.01/0.1/1μS/cm 0.01/0.1 mS/cm | |
Accuracy | ±1.0% FS ±1digit | |
Temperature compensation | (0 ~ 50)°C(manual or automatic) | |
Electrode constant | 0.1 / 1 / 10 cm-1 | |
Temperature | Range | 0~100°C |
Resolution | 0.1°C | |
Accuracy | ±0.5°C±1digit | |
Other Technical Parameters | Data storage | 500 groups |
Storage content | Serial number, date, time, measuring value, measuring unit and temperature value | |
Power | AAA batteries × 3 (1.5V× 3) / DC5V adaptor ( USB port) | |
Dimension & Weight | Meter: (88×170×33 )mm / 313g;Portable case: (360×270×76)mm/1.6kg | |
IP rating | IP57 dustproof and waterproof |
Dissolved Oxygen | Range | (0 ~ 20.00)mg/L(ppm) (0 ~ 200.0)% |
Resolution | 0.01/0.1 mg/L(ppm) 0.1/1 % | |
Indicating value accuracy | ±0.30 mg/L | |
Response time | ≤30 s(25°C, response at 90%) | |
Zero accuracy | ≤ 0.10 mg/L | |
Temperature compensation | (0 ~ 45)°C(automatic) | |
Salinity compensation | (0 ~ 45)ppt(automatic) | |
Barometric pressure compensation | (66.0 ~ 199.9)kPa(manual) | |
Electrode type | Polarographic | |
Temperature | Range | 0~100°C |
Resolution | 0.1°C | |
Accuracy | ±0.5°C±1digit | |
Other Technical Parameters | Data storage | 500 groups |
Storage content | Serial number, date, time, measuring value, measuring unit and temperature value | |
Power | AAA batteries × 3 (1.5V× 3) / DC5V adaptor ( USB port) | |
Dimension & Weight | Meter: (88×170×33 )mm / 313g; Portable case: (480×360×95)mm/3.2kg | |
IP rating | IP57 dustproof and waterproof |
pH | Range | (-2.00 ~ 19.99)pH |
Resolution | 0.01/0.1 pH | |
Accuracy | ±0.01 pH ±1digit | |
Input current | ≤1×10-12 A | |
Input impedence | ≥1×1012 Ω | |
Stability | ±0.01 pH/3h ±1 digit | |
Temperature compensation | (0 ~ 100)°C(manual or automatic) | |
mV | Range | -1,999mV ~ 0 ~ 1,999mV |
Resolution | - 200 mV ~ 0 ~ 200 mV: 0.1 mV;others:1mV | |
Accuracy | ±0.1% FS ±1digit | |
Conductivity | Range | Cond:0~200mS/cm divided into five ranges: (0.00~19.99)μS/cm (20.0~199.9)μS/cm (200~1999)μS/cm(2.00~19.99)mS/cm (20.0~199.9)mS/cm TDS:(0 ~ 100)g/L Salinity:(0 ~ 100)ppt Resistivity:(0 ~ 100)MΩ·cm |
Resolution | 0.01/0.1/1μS/cm 0.01/0.1 mS/cm | |
Accuracy | ±1.0% FS ±1digit | |
Temperature compensation | (0 ~ 50)°C(manual or automatic) | |
Electrode constant | 0.1 / 1 / 10 cm-1 | |
Temperature | Range | 0~100°C |
Resolution | 0.1°C | |
Accuracy | ±0.5°C±1digit | |
Other Technical Parameters | Data storage | 1000 groups |
Storage content | Serial number, date, time, measuring value, measuring unit and temperature value | |
Power | AAA batteries × 3 (1.5V× 3) / DC5V adaptor ( USB port) | |
Dimension & Weight | Meter: (88×170×33 )mm / 313g;Portable case:(480×360×95)mm/3.2kg | |
IP rating | IP57 dustproof and waterproof |
pH | Range | (-2.00 ~ 19.99)pH |
Resolution | 0.01/0.1 pH | |
Accuracy | ±0.01 pH ±1digit | |
Input current | ≤1×10-12 A | |
Input impedence | ≥1×1012 Ω | |
Stability | ±0.01 pH/3h ±1 digit | |
Temperature compensation | (0 ~ 100)°C(manual or automatic) | |
mV | Range | -1,999mV ~ 0 ~ 1,999mV |
Resolution | - 200 mV ~ 0 ~ 200 mV: 0.1 mV;others:1mV | |
Accuracy | ±0.1% FS ±1digit | |
Dissolved Oxygen | Range | (0 ~ 20.00)mg/L(ppm) (0 ~ 200.0)% |
Resolution | 0.01/0.1 mg/L(ppm) 0.1/1 % | |
Indicating value accuracy | ±0.30 mg/L | |
Response time | ≤30 s(25°C, response at 90%) | |
Zero accuracy | ≤ 0.10 mg/L | |
Temperature compensation | (0 ~ 45)°C(automatic) | |
Salinity compensation | (0 ~ 45)ppt(automatic) | |
Barometric pressure compensation | (66.0 ~ 199.9)kPa(manual) | |
Electrode type | Polarographic | |
Temperature | Range | 0~100°C |
Resolution | 0.1°C | |
Accuracy | ±0.5°C±1digit | |
Other Technical Parameters | Data storage | 1000 groups |
Storage content | Serial number, date, time, measuring value, measuring unit and temperature value | |
Power | AAA batteries × 3 (1.5V× 3) / DC5V adaptor ( USB port) | |
Dimension & Weight | Meter: (88×170×33 )mm / 313g;Portable case:(480×360×95)mm/3.2kg | |
IP rating | IP57 dustproof and waterproof |
pH | Range | (-2.00 ~ 19.99) pH |
Resolution | 0.01/0.1 pH | |
Accuracy | ±0.01 pH ±1digit | |
Input current | ≤1×10-12 A | |
Input impedence | ≥1×1012 Ω | |
Stability | ±0.01 pH/3h ±1 digit | |
Temperature compensation | (0 ~ 100) °C(manual or automatic) | |
mV | Range | -1,999mV ~ 0 ~ 1,999mV |
Resolution | - 200 mV ~ 0 ~ 200 mV: 0.1 mV; others:1mV | |
Accuracy | ±0.1% FS ±1digit | |
Conductivity | Range | Cond: 0~200mS/cm divided into five ranges: (0.00~19.99) μS/cm (20.0~199.9) μS/cm (200~1999) μS/cm (2.00~19.99) mS/cm (20.0~199.9) mS/cm TDS:(0 ~ 100) g/L Salinity: (0 ~ 100) ppt Resistivity: (0 ~ 100) MΩ·cm |
Resolution | 0.01/0.1/1μS/cm 0.01/0.1 mS/cm | |
Accuracy | ±1.0% FS ±1digit | |
Temperature compensation | (0 ~ 50) °C(manual or automatic) | |
Electrode constant | 0.1 / 1 / 10 cm-1 | |
Dissolved Oxygen | Range | (0 ~ 20.00) mg/L(ppm) (0 ~ 200.0) % |
Resolution | 0.01/0.1 mg/L(ppm) 0.1/1 % | |
Indicating value accuracy | ±0.30 mg/L | |
Response time | ≤30 s(25°C, response at 90%) | |
Zero accuracy | ≤ 0.10 mg/L | |
Temperature compensation | (0 ~ 45) °C (automatic) | |
Salinity compensation | (0 ~ 45) ppt(automatic) | |
Barometric pressure compensation | (66.0 ~ 199.9) kPa(manual) | |
Electrode type | Polarographic | |
Temperature | Range | 0~100°C |
Resolution | 0.1°C | |
Accuracy | ±0.5°C ±1digit | |
Other Technical Parameters | Data storage | 1000 groups |
Storage content | Serial number, date, time, measuring value, measuring unit and temperature value | |
Power | AAA batteries × 3 (1.5V× 3) / DC5V adaptor ( USB port) | |
Dimension & Weight | Meter: (88×170×33 )mm / 313g; Portable case: (480×360×95)mm/3.2kg | |
IP rating | IP57 dustproof and waterproof |