Type: | Cable & Antenna Analyzer |
---|---|
Certification: | CE |
Customized: | Customized |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Model | CAA-100 |
Frequency Range | 25MHz - 4000MHz |
Frequency Resolution | 100kHz |
Frequency Accuracy | ±25ppm |
Output Power | 0dBm(typ.) |
Measurement Speed | 3.5ms/point |
Data Points | 137, 251, 551, 1103 |
Anti-jamming Capability | |
Frequency | -5dBm |
Channel | +17dBm |
Directivity | 42dB (after calibration) |
Return Loss | |
Return Loss Range | 0 - 60 dB |
Return Loss Resolution | 0.01dB |
VSWR | |
VSWR Range | 1 - 65 |
VSWR Resolution | 0.01 |
Cable Loss | |
Cable Loss Range | 0 - 30dB |
Cable Loss Resolution | 0.01dB |
Distance-to-Fault | |
Distance-to-Fault Return loss Range | 0 - 60 dB |
Distance-to-Fault SWR Range | 1 - 65 |
Measuring Length | 1500m |
Resolution Ratio | ( 1.5×108 ) × (Vp) / (F2-F1) |
Where Vp is the cable's relative propagation velocity. | |
where F2 is the stop frequency and F1 is start frequency | |
Data Points | 137, 251, 551, 1103 |
General Information | |
Connector Type | N-Type female |
Input Impedance | 50 Ohm |
Display | 7 inch resistor touch screen, resolution 800×480 |
Data Interface | One USB Host Port |
One USB Device Port | |
One 10M/100M Adaptive LAN Port | |
Memory Space | >2000 traces |
Internal Battery | 11.1V 7800mAh Rechargeable Lithium Battery |
External Adapter | 110 - 240V, 50 - 60Hz, AC input; 16V, 3.75A, DC output |
Operating Temp. Range | 10ºC - +50 °C |
Storage Temp. Range | 40ºC - +70ºC |
Humidity | 0 - 85% (Non-Condensing) |
Weight | 2.5kg (Suttle) |
Dimensions (L x W x H) | 290×175×75mm |
TPM Module (Optional)--RF Terminal Power Meter | |
Frequency Range | 50 - 4000MHz |
Power Range | -40 - 20 dBm |
Maximum Power | <23 dBm |
Measure Uncertainty | ≤ +/-0.3dB (15ºC - 35ºC) |
≤ +/-0.5dB( 0ºC - 50ºC) | |
Input VSWR | <1.2 |
Burst Width | 1µs - 60ms |
Min Repetition Period | 15Hz |
Video Band | 5MHz |
Minimum Pulse Width | 200ns |
Time Resolution | 0.1µs,1µs,15µs,150µs |
Peak Average Ratio | <12dB |
CCDF Range | 0.1% - 100% |
CCDF Uncertainty | ±3% |
Duty cycle | 0.1% - 100% |
Power Supply | USB |
Operating Temp. Range | 0ºC - 50ºC |
Storage Temp. Range | -20ºC - 70ºC |
Humidity | 0 - 85% (Non-Condensing) |
Weight | 0.3kg |
Dimensions (L x W x H) | 105(125)×45×35mm |
Anti-vibration properties | Conform to MIL-PRF-28800F class 3 |
Elect. Compatibility Characteristics | Conform to EMC GB/T 18268-2000 |
DPM Module(Optional)-RF In Line Digital Power Meter | |
Average Power Measurement | |
Frequency Range | 300-4200MHz |
Power Range | 100mW-200W |
Dynamic Range | ≥33 dB |
Insertion Loss | ≤0.1 dB |
VSWR | 1.05 to 99.9 |
Directivity | ≥30 (<3GHz); ≥28 (>3GHz) |
Accuracy | ±4% |
Impedance | 50Ω |
Connector | N (Female) |
Data Interface | USB |
Peak Power Measurement | |
Peak Power Range | 100mW to 500W |
Peak Power Accuracy | Burst width >200us: ±7%; 1us<Burst width< 200us: ±10%; 0.5us<Burst width< 1us: ±15%; Burst width< 0.5us: ±20%; |
Peak Average Ratio | 0 to12dB |
CCDF | |
Measurement Range | 0.1 to 100% |
Measurement Accuracy | ±3% |
Threshold Measurement Range | 0.05W to 500W |
Burst Power | |
Burst Power Range | 100mW to 200W |
Burst Width | 1us to 60ms |
Min. Measurement Frequency | 15Hz |
Measurement Accuracy | ±6% |
Duty Cycle | 0.0001 to 1 |
Others | |
Power Supply | USB |
Operating Temperature | -10ºC to50ºC |
Storage Temperature | -20ºC to70ºC |
Relative Humidity | 0 to 85% (Non-condensing) |
Weight | 0.48kg |
Dimensions (H×W×T) | 130××124×34mm |