After-sales Service: | 1 Year |
---|---|
Warranty: | 1 Year |
Transport Package: | Carton |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SR2829HF Anticorrosion Coating Thickness Gauge Applications: The F probes measure the thickness of non-magnetic materials (e.g. paint, plastic, porcelain enamel, copper, zinc, aluminum, chrome etc.) on materials of iron, often used to measure the thickness of galvanizing layer, lacquer layer, porcelain enamel layer, phosphate layer, copper tile, aluminum tile, some alloy tile, paper etc. Features: -The F probes measure the thickness of non-magnetic materials on magnetic materials. -Two measurement mode: Single and Continuous (Notice: Continuous mode is convenient to measure the coating thickness of curved objects and tiny objects.) -Metric/imperial system selectable. -Manual or automatic shut down. -Auto memory of calibration value, and auto recognize the substrate. -Operation process have buzzing reminder, while no buzzing in continuous mode. -Use "USB data output" to connect with PC. -Provide "Bluetooth™ data output" choice. Specifications:
|
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SR2701 Series Coating Thickness Meter Model: SR2701F, SR2701N, SR2701FN Description: It can measure the thickness of non-magnetic coating layers on magnetic substrate. Such as: (aluminum, chrome, copper, enamel, rubber, paint) on magnetic substrate(steel, iron, alloy and magnetic stainless steel). It can measure the thickness of non-metals coatings layers covered on non-magnetic metals substrate. Such as: (enamel, rubber, paint, vanish, plastic anodic-oxide layer) covered on non-magnetic metals substrate (aluminum, brass, zinc and nonmagnetic stainless steel). The gauge have data storage, the USB interface, it can save 1173 measuring-records, each record contains the information of measuring-results and measuring-time, it's very useful for you to control the quality of your products. Characteristic: * Small style design, conveniently carry * Complete intelligentized design, easily operate * Rapid measure, excellent repeated performance * Zero adjustment, second point adjustment * LCD digital display * The metric system /England system unit transform * Automatic probe recognition * There is bee ring song prompt during operation * Manual or automatic shut down and accurate indication of power * data saving(1173) * time tracking, can check the time of the record * USB interface, the saving data can be read by U disk. Specification: * Range: 0-1000um * Power:2*AAA (CR1220) clock (CR1220) * Accuracy: Zero adjustment: ± (3%H±1.5); two point adjustment: ± (1%~3%H±1.5) * Resolution: 0.1um (0~99.9um); 1um (over 100um) * Environment temperature: 0-40°C * Relative humidity: ≤85% * Minimum substrate:10*10mm * Minimum Curvature: Convex: 5mm, concave: 25mm * Thinnest substrate: 0.5mm * Weight: 200g * Dimension: 100mm*65mm*25mm |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
SR2830F Film/Coating Thickness Gauge (F type) Measuring range: 0~1800µm Accuracy: ± (3%H±1µm) Resolution: 0.1µm (<100µm) or 1µm(>100µm) Use Hi-sensibility sensor for precise measurement Zero point, two point and basic, three different calibration Measuring mode: Single, Continually and Difference Data store/ Data recall/ Data delete function Data Analysis: Average, Maximum, Minimum, Standard deviation and measuring times Beep sound indication Measure in Metric/Imperial LCD backlight display Low battery indication Auto power off Packing method: Gift box + PP box Power supply: 9V battery Weight: 147g (without battery) Dimension: 67*30*183mm |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SR2831F Film/Coating Thickness Gauge (F type) Measuring range: 0~1800µm Accuracy: ± (3%H±1µm) Resolution: 0.1µm (<100µm) or 1µm(>100µm) Use Hi-sensibility sensor for precise measurement Zero point, two point and basic, three different calibration Measuring mode: Single, Continually and Difference Data store/ Data recall/ Data delete function Data Analysis: Average, Maximum, Minimum, Standard deviation and measuring times Beep sound indication Measure in Metric/Imperial LCD backlight display Low battery indication Auto power off Packing method: Gift box + PP box Power supply: 9V battery Weight: 147g (without battery) Dimension: 67*30*183mm |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SR2831N Film/Coating Thickness Gauge (N type) *Measuring range: 0~1500µm *Accuracy: +/- (3%H+/-1µm) *Resolution: 0.1µm (<100µm) or 1µm(>100µm) *Use Hi-sensibility sensor for precise measurement *Zero point, two point and basic, three different calibration *Measuring mode: Single, Continually and Difference *Data store/ Data recall/ Data delete function *Data Analysis: Average, Maximum, Minimum, Standard deviation and measuring times *Beep sound indication *Measure in Metric/Imperial *LCD backlight display *Low battery indication *Auto power off *Packing method: Gift box + PP box *Power supply: 3*1.5V AAA battery *Weight: 250g (without battery) *Dimension: 70*145*28mm |