Sr2810n Micro Coating Thickness Meter

Product Details
After-sales Service: 1 Year
Warranty: 1 Year
Transport Package: Carton
Gold Member Since 2006

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

to see all verified strength labels (19)
  • Sr2810n Micro Coating Thickness Meter
  • Sr2810n Micro Coating Thickness Meter
  • Sr2810n Micro Coating Thickness Meter
  • Sr2810n Micro Coating Thickness Meter
  • Sr2810n Micro Coating Thickness Meter
  • Sr2810n Micro Coating Thickness Meter
Find Similar Products

Basic Info.

Model NO.
SR2810N
Specification
CE
Trademark
ShowRange
Origin
Shanghai, China
HS Code
9025800000
Production Capacity
5000PCS/Per Year

Product Description

Sr2810n Micro Coating Thickness Meter Sr2810n Micro Coating Thickness Meter
SR2810F Micro Coating Thickness Meter
Features:

* Specially for the thickness measurement of coating on small workpiece.
* Measuring methods: magnetic induction (F). 
* Two measurement mode: Single and Continuous (Notice: Continuous mode is convenient to measure the coating thickness of curved objects and tiny objects.)
* Metric/imperial system selectable.
* Manual or automatic shut down.
* Auto memory of calibration value,and auto recognize the substrate.
* Operation process have buzzing reminder,while no buzzing in continuous mode.
* Use "USB data output" to connect with PC.
* Provide "Bluetooth ™ data output"choice.
* Separate Type, measurements can be more flexibility.
SR2810N Micro Coating Thickness Meter
Features:

* Specially for the thickness measurement of coating on small workpiece.
* Measuring methods: eddy current (N).
* Two measurement mode: Single and Continuous (Notice: Continuous mode is convenient to measure the coating thickness of curved objects and tiny objects.)
* Metric/imperial system selectable.
* Manual or automatic shut down.
* Auto memory of calibration value,and auto recognize the substrate.
* Operation process have buzzing reminder,while no buzzing in continuous mode.
* Use "USB data output" to connect with PC.
* Provide "Bluetooth data output" choice.
* Separate Type, measurements can be more flexibility.
 
Specifications Model SR2810F Model SR2810N
Operating Principle Magnetic Induction (F)   Eddy Current (NF)
Measuring Range 0~200um / 0~8mil
Resolution 0.1um
Min. Radius Workpiece convex 2mm / concave 4mm
Min. Measuring Area 2mm
Min. Sample Thickness 0.1mm
Accuracy ± 1~3%n or ± 2.5um 
Auto Power Off Yes
Metric / Imperial Convertible
Battery Indicator Low Battery Indicator
Operating Conditions Temp. 0~40°C, Humidity: 10~90%RH
Power Supply 4 x 1.5V AAA (UM-4) Battery
Dimensions 140 x 72 x 34mm ( 5.5 x 2.8 x 1.3inch )
Weight 215g (Not Including Batteries)
Standard delivery Main Unit Main Unit
Probe (F Type) Probe (NF Type)
Calibration Base Set (F Type) CTG-BS Calibration Base Set (NF Type) CTG-BS
Calibration Foils CTG-CF (1set, 4pieces) Calibration Foils CTG-CF (1set, 4pieces)
Carrying Case Carrying Case
Operation Manual Operation Manual
Optional accessories  1. USB, RS-232C data cable with software
 2. Bluetooth data out put with software
   
Sr2810n Micro Coating Thickness Meter Sr2810n Micro Coating Thickness Meter
SR2810A Digital Coating Thickness Meter
(F & NF type)
Features:
* Two measuring methods: magnetic induction (F) and eddy current (N)
* Two measurement mode: Single and Continuous (Notice: Continuous mode is convenient to measure the coating thickness of curved objects and tiny objects.)
* Metric/imperial system selectable.
* Manual or automatic shut down.
* Auto memory of calibration value, and auto recognize the substrate.
* Operation process have buzzing reminder, while no buzzing in continuous mode.
* Use "USB data output" to connect with PC. 
* Provide "Bluetooth ™ data output" choice.
* Separate Type can provide several type probe, measure can be more flexibility.

Applications:
The F probes measure the thickness of non-magnetic materials (e.g. paint, plastic, porcelain enamel, copper, zinc, aluminum, chrome etc.) on magnetic materials (e.g. iron, nickel etc.) . often used to measure the thickness of galvanizing layer, lacquer layer, porcelain enamel layer, phosphate layer, copper tile, aluminum tile, some alloy tile, paper etc. The N probes measure the thickness of non-magnetic coatings on non-magnetic metals. It is used on anodizing, varnish, paint, enamel, plastic coatings, powder, etc. applied to aluminum, brass, non-magnetic stainless steel, etc.
SR2810B Digital Coating Thickness Meter
(F & NF type)
Features:
* Can store the new data in 99 groups.
* Two measuring methods: magnetic induction (F) and eddy current (N).
* Two measurement mode: Single and Continuous (Notice: Continuous mode is convenient to measure the coating thickness of curved objects and tiny objects.)
* Metric/imperial system selectable.
* Manual or automatic shut down.
* Auto memory of calibration value, and auto recognize the substrate.
* Operation process have buzzing reminder, while no buzzing in continuous mode.
* Use "USB data output" to connect with PC. 
* Provide "Bluetooth ™ data output" choice.
* Separate Type can provide several type probe, measure can be more flexibility.
Applications:
The F probes measure the thickness of non-magnetic materials (e.g. paint, plastic, porcelain enamel, copper, zinc, aluminum, chrome etc.) on magnetic materials (e.g. iron, nickel etc.) . often used to measure the thickness of galvanizing layer, lacquer layer, porcelain enamel layer, phosphate layer, copper tile, aluminum tile, some alloy tile, paper etc. The N probes measure the thickness of non-magnetic coatings on non-magnetic metals. It is used on anodizing, varnish, paint, enamel, plastic coatings, powder, etc. applied to aluminum, brass, non-magnetic stainless steel, etc.
Specifications Model SR2810A SR2810B
Operating principle Magnetic Induction & Eddy Current (F&NF) Magnetic Induction & Eddy Current (F&NF)
Measuring range  0~2000 um / 0~80 mil
Resolution 0.1 um / 1 um
Min. Radius Workpiece   F Type: convex 1.5 mm / concave 25 mm, NF Type: convex 3 mm / concave 50 mm
Min. Measuring Area 6 mm
Min. Sample Thickness 0.3 mm
Accuracy ± 1~3%n or ± 2.5 um
Auto Power Off Yes
Metric / Imperial Convertible
Battery Indicator Low Battery Indicator
Operating Conditions  Temp. 0~40 °C, Humidity: 10~90 %RH
Power Supply * 1.5 V AAA (UM-4) Battery
Dimensions 140 * 72 * 34 mm ( 5.5 * 2.8 * 1.3 inch )
Weight 215g (Not Including Batteries)
Standard delivery Main Unit 1
Probe (F & NF 2 in 1) 1
Calibration Base Set 1  F Type & 1 NF Type
Calibration Foils 4
Carrying Case 1
Operation Manual 1
Optional accessories USB Cable & software, Bluetooth data output
   
 
Sr2810n Micro Coating Thickness Meter
 
Sr2810n Micro Coating Thickness Meter
SR2807 Digital Coating Thickness Gauge
(F & NF type)
Features
* It meets the standards of both ISO2178 and ISO-2360 as well as DIN, ASTM and BS. Suitable for the laboratory and for use in harsh field conditions.
* The F probes measure the thickness of non-magnetic materials (e.g. paint, plastic, porcelain enamel, copper, zinc, aluminum, chrome etc.) on magnetic materials (e.g. iron, nickel etc.) . often used to measure the thickness of galvanizing layer, lacquer layer, porcelain enamel layer, phosphate layer, copper tile, aluminum tile, some alloy tile, paper etc.
* The N probes measure the thickness of non-magnetic coatings on nonmagnetic metals. It is used on anodizing, varnish, paint, enamel, plastic coatings, powder, etc. applied to aluminum, brass, non-magnetic stainless steel, etc.
* Automatic substrate recognition.
* Manual or automatic shut down.
* Two measurement mode: Single and Continuous
* Wide measuring range and high resolution.
* Metric/Imperial conversion.
* Digital display gives exact reading with no guessing or errors.
* Can communicate with PC computer for statistics and printing by the optional cable and the software for RS232C interface .
SR2808 Digital Coating Thickness Gauge
(F & NF type)
Features
* It meets the standards of both ISO2178 and ISO-2360 as well as DIN, ASTM and BS. Suitable for the laboratory and for use in harsh field conditions.
* The F probes measure the thickness of non-magnetic materials (e.g. paint, plastic, porcelain enamel, copper, zinc, aluminum, chrome etc.) on magnetic materials (e.g. iron, nickel etc.) . often used to measure the thickness of galvanizing layer, lacquer layer, porcelain enamel layer, phosphate layer, copper tile, aluminum tile,

some alloy tile, paper etc.
* The N probes measure the thickness of non-magnetic coatings on nonmagnetic
metals. It is used on anodizing, varnish, paint, enamel, plastic coatings, powder, etc. applied to aluminum, brass, non-magnetic stainless steel, etc.
* Automatic substrate recognition.
* Manual or automatic shut down.
* Two measurement mode: Single and Continuous
* Wide measuring range and high resolution.
* Metric/Imperial conversion.
* Digital display gives exact reading with no guessing or errors.
* Can communicate with PC computer for statistics and printing by the optional cable and the software for RS232C interface .
   
Specifications Model SR2807 SR2808
Operating principle (F& NF) (F & NF)
Display 4 digits, 10 mm LCD, backlit
Measuring range 0-1250µm/0-50mil (other range may be specified)
Resolution 0.1 µm (0~99.9µm); 1 µm (over 100µm)
Accuracy ±1~5%n or 3.5 µm or 0.1mil (Whichever is the greater)
Two measurement mode Single and Continuous
Metric/Imperial convertible
Operating condition Temp. 0~50°C, Humidity <80%
PC interface with RS-232C interface
Auto switch off
Power supply 2x1.5 AAA(UM-4) battery
Dimensions & weight 102x35x23 mm (4.0x1.4x0.9 inch)
& about 40g (in-built probes) (not including batteries)
Standard delivery Main unit 1
F Type probe 1 1
NF Type probe 1 1
Substrate (Iron) 1 1
Substrate (Aluminum) 1 1
Calibration foil set 1 set 
Carrying case 1
Instruction manual 1
Optional accessories RS-232C Cable & software, USB Cable & software, Bluetooth data output

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier