Thru-Paint (Through coating, Through paint) ultrasonic thickness gauge SR1911D
Measuring range:
0.8mm to 300mm; 0.031in to 11.81in in standard mode
3.0mm to 18.0mm; 0.118in to 0.709in in through coating mode
Depending on probe, material and surface condition
Digital resolution:
0.001in or 0.1mm (less than SR1912D)
Units: Selectable: Inch or mm
Display:
128× 64 DOT-matrix LCD screen (1.65in× 2.24in; 42mm× 57mm)
EL backlight and switchable contract ratio
Digit height: 0.54in or 13.75mm
Measurement update rate:
4 Hz in standard measurement mode
25 Hz in MIN capture mode
Material velocity range:
1000 to 9999 m/s; 0.039 to 0.394 inch/µ S
Power:
Two 1.5V AA alkaline batteries
Warning with low battery voltage
Operating time:
Up to 200 hours (without backlight) with alkaline batteries, depending on operating mode
Auto shut-off: After 5 minutes of non-use
Probe zero adjustment:
Selectable: 1-point calibration: Normal measurement
2-point calibration: Curve surface measurement or other special application with a high precision
V-path correction: Automatic
Size: 5.86in× 2.87in× 1.25in; 149mm× 73mm× 32mm (H× W× D)
Weight: 200g; 7oz (including batteries)
Data logger capacity:
Up to 500 readings can be divided into a maximum of 5 files (user-selectable)
Measuring error:
Up to 1in: ± 0.002in or ± 0.1mm
Above 1in: ± 1%H
H is the height of the testing object
Repeatability: ± 0.001in or ± 0.1mm
Application software: UMVIEW
Interfaces:
Serial RS 232C port in combination with a communicative cable;
Data transfer parameters: 8 bits, 1 stop bit, 9600 baud, no parity.
Standard package:
SR1911D thickness gauge, Standard probe (PT-08)
Carrying case, Two 1.5V AA alkaline batteries
Couplant, Operating manual
Optional accessories:
Attachable rubber case
Numerous special probes on request
Couplants and high-temperature couplant
4-step/6-step block for calibration
Data transmission cable
Application software
Thru-Paint (Through coating, Through paint) ultrasonic thickness gauge SR1912D
Measuring range:
0.8mm to 300mm; 0.031in to 11.81in in standard mode
3.0mm to 18.0mm; 0.118in to 0.709in in through coating mode
Depending on probe, material and surface condition
Digital resolution:
H<4in: 0.001in /0.01in or 0.01mm/0.1mm; H≥ 4in: 0.01in or 0.1mm
Units: Selectable: Inch or mm
Display:
128× 64 DOT-matrix LCD screen (1.65in× 2.24in; 42mm× 57mm)
EL backlight and switchable contract ratio
Digit height: 0.54in or 13.75mm
Measurement update rate:
4 Hz in standard measurement mode
25 Hz in MIN capture mode
Material velocity range:
1000 to 9999 m/s; 0.039 to 0.394 inch/µ S
Power:
Two 1.5V AA alkaline batteries
Warning with low battery voltage
Operating time:
Up to 200 hours (without backlight) with alkaline batteries, depending on operating mode
Auto shut-off: After 5 minutes of non-use
Probe zero adjustment:
Selectable: 1-point calibration: Normal measurement
2-point calibration: Curve surface measurement or other special application with a high precision
V-path correction: Automatic
Size: 5.86in× 2.87in× 1.25in; 149mm× 73mm× 32mm (H× W× D)
Weight: 200g; 7oz (including batteries)
Data logger capacity:
Up to 500 readings can be divided into a maximum of 5 files (user-selectable)
Measuring error:
Up to 1in: ± 0.002in or ± 0.05mm
Above 1in: ± 0.5%H
H is the height of the testing object
Repeatability: ± 0.001in or ± 0.025mm
Application software: UMVIEW
Interfaces:
Serial RS 232C port in combination with a communicative cable;
Data transfer parameters: 8 bits, 1 stop bit, 9600 baud, no parity.
Standard package:
SR1912D thickness gauge, Standard probe (PT-08)
Carrying case, Two 1.5V AA alkaline batteries
Couplant, Operating manual