Display: | Digital |
---|---|
Portable: | Portable |
Appliance: | Food Analysis, Medical Research, Biochemistry |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Measuring range | 0.00~14.00PH |
Accuracy | ±0.1PH |
Resolution | 0.01PH |
Operating Temperature | 0ºC~50ºC |
Automatic Temperature Compensation | 0ºC~50ºC |
Power Supply | 4*1.5V(AG13) |
Calibration | Manual 1 point |
Dimensions | 170mm*33mm*20mm |
Weight | 69g |
Measuring range | 0.00~14.00PH |
Accuracy | ±0.1PH |
Resolution | 0.01PH |
Operating Temperature | 0ºC~50ºC |
Automatic Temperature Compensation | 0ºC~50ºC |
Power Supply | 4*1.5V(AG13) |
Calibration | Manual 1 point |
Dimensions | 175mm*30mm*22mm |
Weight | 67g |
Model | PH-009(II) | PH-009(II)A |
Measuring range | 0.00~14.00PH | |
Accuracy | ±0.1PH | |
Resolution | 0.01PH | |
Operating Temperature | 0ºC~50ºC | |
Automatic Temperature Compensation | 0ºC~50ºC | |
Plug | Fixed Electrode | BNC |
Power Supply | 4*1.5V(AG13) | |
Dimensions | 170*36*23(mm3) | |
Weight | 85g | 105g |
Model | PH-03(II) | PH-03(II)L | PH-03(II)A | PH-03(II)B | PH-03(II)C |
Measuring range | 0.00~14.00pH | ||||
Accuracy | ±0.1PH | ||||
Resolution | 0.01PH | ||||
Operating Temperature | 0ºC ~50ºC | ||||
Automatic Temperature Compensation | 0ºC ~50ºC | ||||
Electrode | Fixed Electrode | Extended Fixed Electrode | BNC+1m cable | BNC | For cheese & milk & soft soil testing |
Power Supply | 4*1.5V(AG13) | ||||
Dimensions | 165*26*26 mm | 120mm*26mm*26mm | |||
Weight | 63g | 65g | 70g | 68g |
Model | PH-061 |
Measuring range | 0.00~14.00PH |
Accuracy | ±0.1PH |
Resolution | 0.01PH |
Operating Temperature | 0ºC~50ºC |
Automatic Temperature Compensation | 0ºC~50ºC |
Power Supply | 4*1.5V(AG13) |
Dimensions | 155mm*31mm*16mm |
Weight | 60g |
Range |
mV | 0~±1999mV |
pH | 0.00 to 14.00 pH | |
Temperature | 0 to 55°C | |
Resolution | mV | 1 mV |
pH | 0.01 pH | |
Temperature | 0.1°C | |
Accuracy | mV | ±5mV |
pH | ±0.1 pH | |
Temperature | ±1°C | |
Temperature Compensation | 0 to 50°C | |
Electrode | replaceable pH electrode (included); fixed ORP sensor |
|
Power Supply | 4 x 1.5V(AG13) | |
Environment | 0 to 50°C | |
Dimensions | 170 x 40 x 23 mm | |
Weight | 100 g | |
Packing | 50PCS/CTN, CTN SIZE: 50*41*25CM, G.W.: 16.5KGS |
pH | Range | -2.00 to 16.00 pH |
Accuracy | ±0.01 pH±1 digit | |
Calibration | 1 to 3 points Auto. Calibration (recognizes 5 types of standards) | |
mV | Range | ±1000 mV |
Accuracy | ±0.2% F.S | |
Conductivity (EC) | Range | 0 to 20.0 mS/cm |
Accuracy | ±1% F.S | |
Calibration | 1 to 3 points Auto. Calibration | |
TDS | Range | 0 ppm to 10.0 ppt (10,000 ppm) |
TDS Factor | 0.4 tp 1.0 | |
Salinity | Range | 0 to 10.0 ppt (10,000 ppm) |
Resistivity | Range | 50Ω·cm to 20MΩ·cm |
Temperature | Range | 0 to 50˚C (32 to 122˚F) |
Others | Application | General water solutions |
Temp. Compensation | Automatic 0 to 50˚C (32 to 122˚F) | |
IP Rating | IP67 Waterproof and Dustproof | |
Power Supply | DC3V AAA batteries *4 | |
Compatible Probes | PH-60-DE, PH-60S-DE, PH-60F-DE, ORP-60-DE, EC-60-DE | |
Alarm Function | Yes (customizable in ZenTest App) | |
Automatic Hold | Yes (5 to 20 seconds, customizable in ZenTest App) | |
Calibration Reminder | Yes (by hours/days, customizable in ZenTest App) | |
ZenTest App Functions (Bluetooth, iOS/Android) | Four Display Modes | Yes |
Cloud Data Management | aYes | |
Smart Self- Diagnosis | Yes | |
Step-by-step calibration guide | Yes |
Range |
PH:0.00~14.00; mV:0~±1999mV ºC:0~100ºC |
Resolution |
PH:0.01PH mV:1mV ºC:0.1ºC |
Accuracy |
PH:±0.01PH mV:±1mV±1digit ºC:±0.4ºC |
Calibration | 1point or 2point |
A T C | 0ºC~95ºC |
Power | 9V battery |
Operating Conditions | 0~60ºC RH≤95% |
Dimensions | 180×82×45mm |
Weight | 290g |
Model | SR220 |
pH Range | -2.00~16.00pH |
pH Accuracy | ±0.01pH |
mV Range | -1999~1999mV |
mV Accuracy | ±1mV |
Calibration Points | 2 points |
Calibration Solutions | USA (pH4.01, 7.00, 10.01) |
Temperature Range | 0~100°C, 32~212°F |
Temperature Accuracy | ±1°C |
Temperature Calibration | Manual |
Temperature Compensation | 0~100°C, 32~212°F, Automatic or Manual |
Hold Function | Manual |
Memory | 50 data sets with Date/Time stamping |
Output | USB Communication Interface |
Connector | BNC |
Power Requirements | 1×9V/800mA battery |
Battery Life | Approximately 150 hours |
Dimensions | 185(L)×88(W)×32(H)mm |
Weight | 300 grams |
Order code and Accessories: | |
Order Code | Accessories |
SR220-UK | P11 pH Electrode (Made in UK), Standard pH Buffers, Temperature probe, Battery, Carrying Case |
SR220-CN | E65-1 pH Electrode (Made in China), Standard pH Buffers, Temperature probe, Battery, Carrying Case |
SR220-ORP | E65-1 pH Electrode, 501 ORP Electrode, Standard pH Buffers, Temperature Probe, Battery, Carrying Case |
Measuring range | pH: (-2.00 ~ 19.99)pH mV: ±1999mV |
Resolution | pH: 0.1/0.01pH mV: 1mV |
Accuracy | pH: ±0.01pH mV: ±0.1%FS |
Stability | ±0.01 pH/3h |
Temp. compensation range | (0 ~ 100) ºC (ATC) |
Data storage | 200 groups |
Storage content | Series number, measuring value, measuring unit and temperature |
Power | Two AA batteries (1.5V x2) |
Size and weight | Meter: (65×120×31)mm/180g Carrying case:(255 x 210x 50)mm/790g |
Quality and safety certification | ISO9001:2000, CE and CMC |
Range | PH: 0.00~14.00 mV: 0~±1999mV ºC: 0~100ºC EC: 0.00~19.99ms/cm CF: 0.0~199.9CF TDS: 10~19990ppm |
Resolution | PH: 0.01PH mV: 1 mV ºC: 1ºC EC: 0.01 ms/cm CF: 0.1CF TDS: 10 ppm |
Accuracy | PH: ±0.01PH mV: ±1mV ºC: ±0.4ºC EC.CF.TDS: ±2%F.S |
Calibration | 1point or 2point |
A T C | 0ºC~95ºC |
Power | DC9V/200mA or Rechargeable battery |
Operating Conditions | Temperature: 5~60ºC Humidity: 95% maximum |
Standard electrode | PH electrode, thermo electrode |
Dimensions | 208×200×76mm |
Model | PHS210 |
pH Range | -1.00~15.00pH |
pH Accuracy | ±0.01pH |
mV Range | -1000~1000mV |
mV Accuracy | ±1mV |
Calibration Points | 1, 2 or 3 points |
Calibration Solutions | USA (pH4.01/7.00/10.01) or NIST (pH4.01/6.86/9.18) |
Temperature Range | 0~105°C, 32~221°F |
Temperature Accuracy | ±1°C |
Temperature Calibration | Manual |
Temperature Compensation | 0~100°C, 32~212°F, Automatic or Manual |
Auto-Off | Manual or Automatic (180 minutes after last key pressed) |
Hold Function | Manual or Automatic endpoint |
Reset Function | Yes |
Connector | BNC |
LCD Display | Custom Dual-Display LCD (135×75mm) |
Power Requirements | DC9V, using AC adapters, 220VAC/50Hz |
Dimensions | 210(L)×205(W)×75(H)mm |
Weight | 1.2kg |
Model Specifications | SRS-5 | |
Parameters | pH / mV (ORP) / °C | |
Range |
pH | -2.000~18.000 |
mV | ±1999.99 | |
Temperature | -5.0~105.0°C | |
Resolution | pH | 0.1/0.01/0.001 |
mV | 0.1/ 0.01 | |
Temperature | 0.1°C | |
Accuracy | pH | ±0.002±1 bit |
mV | ±0.03%FS | |
Temperature | ±0.2°C±1 bit | |
Stability | (±0.002pH±1 bit) /3h | |
Temp compensation | Manual/Auto (-5.0~105.0) °C | |
Calibration points | pH: up to five; | |
Buffer recognition | Automatic: USA/NIST | |
Data storage | 200 data with time-and-date | |
View, delete and print | Yes | |
Display | Touch, big LCD screen | |
Output | RS-232, USB | |
Software | 1.1DC | |
Power | AC (220±22)V; (50±1)Hz | |
Case outside serial No. | WXS-A009-1 | |
Dimension(mm), weight(kg) | 250*195*100, 2 | |
Packing Size (mm) (Carton box) | 370*310*340 | |
Gross Weight: (kg) (Carton box) | 4 |
Measuring range | (-1.999 to 19.999) PH |
Resolution | 0.1/0.01/0.001 PH |
Accuracy | Meter: ±0.002 PH, connect meter with electrode: ±0.01PH |
Input current | ≤1×10-12 A |
Input impendance | ≥3×1012 Ω |
Stability | ±0.002 PH/3h |
Temp. compensation range | (0 to 100) ºC(automatic or manual) |
Measuring range (mV/ORP/EH) | -1999.9 mV to 0 to 1999.9mV |
Resolution | 0.1mV |
Accuracy | ±0.03% FS |
Measuring range | 0.00 to 14.00pX |
Display unit | pX, mol/L, mg/L, ppm |
Accuracy | Meter: ±0.5 % reading(monovalent), ±1.0 % reading (bivalent) |
Temp. compensation range |
0 to 60 ºC(automatic or manual) |
Measuring range |
Conductivity: (0.00 to 20.00)μS/cm (20.0 to 200.0)μS/cm (200 to 2000)μS/cm (2.00 to 20.00) mS/cm (20.0 to 200.0) mS/cm (200 to 2000) mS/cm(K=10) Resistivity: (0 to 100) MΩ·cm TDS: (0 to 100) g/L Salinity: (0 to 100) ppt |
Resolution | 0.01/0.1/1μS/cm 0.01/0.1/1 mS/cm |
Accuracy |
Meter: ±0.5% FS,connect meter with electrode: ±0.80% FS |
Temp. compensation range | (0 to 50) ºC(automatic) |
Electrode constant | 0.1 / 0.5 / 1 / 5 / 10 / 50 /100 cm-1 |
Reference temperature | 25 ºC, 20 ºCand 18 ºC |
Measuring range | (0 to 40.00) mg/L(ppm) (0 to 200.0) % |
Resolution | 0.1/0.01 mg/L(ppm) 1/0.1% |
Accuracy | Meter: ±0.10 mg/L, connect meter with electrode: ±0.40 mg/L |
Response time | ≤30 s (25 ºC, 90% response |
Residual current |
≤0.1 mg/L |
Temp. compensation range |
(0 to 45) ºC(automatic) |
Salinity compensation range |
(0 to 45) ppt(automatic) |
Air pressure compensation range | (80 to 105) kPa(automatic) |
Automatic calibration | Air saturated by water; water saturated by air |
Electrode type | Polarogram type |
Measuring range | -10 ºCto 110 ºC |
Resolution | 0.1 ºC |
Accuracy | 5 to 60 ºC range: ±0.4 ºC other range: ±0.8 ºC |
Data storage | 300 groups |
Storage content | Measuring value series number, measuring value, temperature, ATC or MTC state, measuring date and time |
Power | DC9V/300mA |
Communication connector | RS-232 |
Size and weight | 160 x 190 x 70mm/880g |
Quality and safety certification |
ISO9001: 2000, CE and CMC |